Back

WA South Metropolitan Health Service

Fremantle Hospital O and Q block tunnel ceiling rectification works

AwardedSelect Tender

Details

Awarded
Select tender
This is a select tender. Details and access to the source may be limited to invited suppliers only.

Description

A section of ceiling in Fremantle Hospital’s service tunnel, between O-block and Q-block, requires removal and reinstatement. This RFQ is seeking a price for all works associated, inclusive of building and plumbing works. Scope of works inclusions: Rectification of tunnel ceiling in accordance with the recommendations of the Structural Engineer (Attachment 1) including the lowering of services in the service tunnel ensuring little to no impact on site operations Installation of a concrete culvert for steam condensate pipework in accordance with the recommendations of the Structural Engineer (Attachment 2) Removal and reinstatement (redirection) of steam condensate and stormwater pipework to enable access to the tunnel ceiling from above Provision and installation of a trafficable pit cover for the steam blowdown pit. Scope of works exclusions: Reinstatement of bitumen Removal and reinstatement of earthing cable from above the tunnel (to be provided by the hospital’s electrical contractor) – these works will need to be accommodated by the building contractor. Please note the successful contractor will be required commence this works package within 14 days of the contract award and liaise with the Structural Engineer who has already been engaged as part of this project. Please provide an indicative program of works as part of your submission to this RFQ. Please also note that a small amount of Abestos Fines (fibre cement and loose bundles) has been detected in the soil within the construction zone. Levels detected were less than the adopted guildeline and have therefore been deemed low-medium risk, meaning works can progress under safe management protocols. Fremantle Hospital have engaged a specialist consultant to develop an Asbestos Management Plan and work with the successful contractor to understand proposed works methodology, SWMS and ensure safe controls are in place. The successful contractor will be required to adhere to relevant Occupation Safety and Health regulations, including but not limited to traffic management (if required). All submissions to this RFQ will be assessed against the following qualitative criteria: Organisational Capability and Capacity Demonstrated Experience Proposed Methodology and Service Continuity

Request type

Select Tender

TenderHub gathers information continuously from a variety of sources. There may be delays between information being updated at the source and presented here. Always check with the source if you are concerned about currency or accuracy.

Key details

Source
Tenders WA

Briefings & site visits

No briefings or site visits were listed for this tender.

Awarded suppliers

1

Contract awarded

$269,627 awarded to 1 supplier

  • LONGREACH BUILDING SERVICES PTY. LTD. (Longreach Building Services PTY LTD)

    $269,627

    547A Canning Hwy Alfred Cove, Perth WA Australia 6154

See who else bid on this tender

Subscribers see every supplier who bid on this tender, plus its change history and a direct link to the source notice.