The services include design and related services in respect of the following works:

ICT Upgrade – infrastructure to support Army Aviation training, particularly flight management systems. Specific actions include:

  • Provide five (5) new Security Construction and Equipment Committee (SCEC) endorsed pits to replace unserviceable ones

  • Replace 108 pit lids with new SCEC endorsed ones
  • Replace copper cabling with fibre optic.

Electrical System Upgrade - services to support Base operations. Specific actions include:

  • Restore ISS2 to serviceable condition

  • Upgrade ISS2 – replacement of HV protection relays and auxiliary power, external building to house auxiliary power and switchboard, inclusion of DESN/PCMS cubicle

  • Extend ISS2 switchboard by one panel and install an interconnector cable between ISS1 and ISS2

  • Verify unknown cable details, replace cables to prevent overloads, update documentation and re-evaluate adequacy of cable protection

  • Replace ring mains cables that are non-compliant with Manual of Infrastructure Engineering – Electrical (MIEE)

  • Replace substation 17

  • Rebuild indoor substation 18

  • Replace 13 substations of MIEE non-compliant equipment layout, size or extensibility. Install surge protectors on two transformers

  • Replace Substations 02 and 07, replace Ring Main Units (RMU) of substations 18 and 20, repair RMUs of substations 06 and 10

  • Provide adequate fire protection around four substations

  • Install a site-wide PCMS for connection to RMUs

  • Upgrade kiosk substation Low Voltage ends

Replace four non-compliant switchboards.

Stormwater Upgrade – infrastructure to minimise flooding risk at Base. Specific actions include:

  • Repair/replace culverts/headwalls in poor condition

  • Repair structures (i.e. culverts/headwalls/outlets) identified as being in fair condition

  • Repair/replace section of underground network identified as being in poor condition

  • Repair/replace sections of underground pipe network in fair condition

  • Undertake a flood mitigation strategy to improve capacity and compliance at the Base.

Locations

Request type

Expression of Interest

TenderHub gathers information continuously from a variety of sources. There may be delays between information being updated at the source and presented here. Always check with the source if you are concerned about currency or accuracy.

Key details

Estimated value
$25,000,000 to $35,000,000
Source
AusTender

Briefings & site visits

No briefings or site visits were listed for this tender.

Awarded suppliers

2

Contracts awarded

$3,105,977 awarded to 2 suppliers

See who else bid on this tender

Subscribers see every supplier who bid on this tender, plus its change history and a direct link to the source notice.